Category: Web Monitoring Station for ABB Aurora inverter (ex Power One now Fimer)

ABB PowerOne Aurora Web Inverter Centraline repair E013 error 0

ABB (Power-One) Aurora web inverter monitor (WIM): repair E013 error – 11

I’d like to monitoring my ABB Aurora inverter. So with an WeMos D1 mini I create a centraline with web interface, notification and other.
The monitoring is necessary to find the problems and thanks to the WIM I can promptly fix the error of the inverter E013.

ABB PowerOne Aurora Web Inverter Centraline 3D printed case 0

ABB Aurora web inverter monitor (WIM): 3D printed case to complete project – 10

I’d like to monitoring my ABB Aurora inverter. So with an WeMos D1 mini I create a centraline with web interface, notification and other.
Now a case where you can insert all the component to complete the work.

ABB PowerOne Aurora Web Inverter Centraline PCB Soldering assembly 8

ABB Aurora Web Inverter Monitor (WIM): wiring and PCB soldering – 8

I’d like to monitoring my ABB Aurora inverter. So with an WeMos D1 mini I create a centraline with web interface, notification and other.
Now we must solder and assembly the free PCB that I create for this centraline.

ABB PowerOne Aurora Web Inverter Centraline WIFI configuration and REST Server 0

ABB (Power One) Aurora Web Inverter Monitor (WIM): WIFI configuration and REST Server – 6

I’d like to monitoring my ABB Aurora inverter. So with an WeMos D1 mini I create a centraline with web interface, notification and other.
Here I’d like to explain how to configure WiFi first time and I show REST API of the device.

ABB PowerOne Aurora Web Inverter Centraline Set time and manage battery UPS 0

ABB Aurora web inverter monitor (WIM): set time and manage battery UPS – 5

I’d like to monitoring my ABB Aurora inverter. So with an WeMos D1 mini I create a centraline with web interface, notification and other.
Here we are going to explore how to create an UPS and how correctly set date.

ABB PowerOne Aurora Web Inverter Centraline Debug and notification 0

ABB Aurora web inverter centraline (WIC): debug and notification – 4

I would like to monitor the status of my ABB Aurora inverter (formerly Power One now Fimer). So with a WeMos D1 mini I create a monitoring station with web interface, notifications and more.
Notification is a basic feeature of every monitoring system, here we check how to configure the device to send email with errors.

ABB PowerOne Aurora Web Inverter Centraline Storage devices 0

ABB Aurora Web Inverter Monitor (WIM): Storage devices – 3

I would like to monitor the status of my ABB Aurora inverter (formerly Power One now Fimer). So with a WeMos D1 mini I create a monitoring station with web interface, notifications and more.
Where are we store the data and html page?? In this article the solution.

ABB PowerOne Aurora Web Inverter Centraline Wiring Arduino to RS485 6

ABB Aurora Web Inverter Monitor (WIM): wiring Arduino to RS-485 – 2

I would like to monitor the status of my ABB Aurora inverter (formerly Power One now Fimer). So with a WeMos D1 mini I create a monitoring station with web interface, notifications and more.
Now we are going to wire our Arduino to the Inverter.